NFE SERIES


Negative Flow Exhausting HEPA Filtered Workstation
Free-standing console provides containment of contaminated air through intake at work chamber. The initial prefilter collects gross contaminants, then the air passes through an exhaust HEPA filter (High Efficiency Particulate Air, 99.99% efficient on .3 microns) for removal of the remaining contaminants to .3 microns. Use of exhaust filtration eliminates the need to duct to the outside. Units are individually tested for intake and exhaust velocities as per manufacturer’s specifications, and the exhaust HEPA filter is tested and certified to meet or exceed the specifications for HEPA/ULPA filter installation leak test of Institute of Environmental Sciences and Technology IEST-RP-CC002.2. NOT TO BE USED FOR TOXIC FUME REMOVAL OR WITH ANY COMBUSTIBLE GAS.

SPECIFICATIONS

Three Stage Filtration of Powders

Stage 1: Prefilter-Intake- 2" thick pleated prefilter, 60% efficiency, directly behind protective eggrate screen.

Stage 2: Prefilter-Intake- 3" HEPA (High Efficiency Particulate Air) type, behind pleated prefilter, aerosol challenged, zero probed. Aluminum frame mini-pleat design. Minimum efficiency of 95% at .3 microns.

Stage 3: Filter-Exhaust- 3" HEPA (High Efficieny Particulate Air) type, PSL challenged, zero probed. Aluminum frame mini-pleat design, 99.99% @.3 microns, located at rear of unit.

Airflow- Average measured clean air velocity 120 fpm.

Construction- Standard construction is Woodboard with plastic laminate exterior. Epoxy Painted Steel, 304 or 316L Stainless Steel units are also available. 1/16” laminated work surface and canopy. Clear acrylic side panels for visibility. Front loaded intake HEPA prefilter; top loaded exhaust HEPA filter. Protective plastic eggcrate diffuser screen in front of intake HEPA prefilter, and on top of exhaust HEPA filter.

Electrical & Power Requirements- All electrical components are UL Approved. Standard 115V, 15A 1 Ph, 60 Hz. 15 ft. SJO power cord with 3-prong ground plug.

Motor/Blower Assembly- High efficiency motors to reduce electrical load. Motors are thermally protected & self-lubricating. High capacity metal forward curved blowers within direct drive motors. Fans statically balanced to maintain constant airflow. Motor/blowers are selected to maintain required airflow rate up to double the initial static pressure.

Lighting- Recessed 2 pin fluorescent lighting. 125 ft. candle +/-20 ft. candles. Plastic prismatic lens cover maximizes light diffusion.

Controls- Solid state adjustable airflow control, 70-180 fpm, 15A max. load capacity, externally mounted for adjustment of intake velocity. Individually illuminated switches on face panel for motor & lights.



request Info

640 Herman Road Ste 2 Jackson, NJ 08527   Phone Toll Free 888-399-2464 Local 732-534-5590  Fax 732-534-5589

 
 

 

 

 

 

 

 

 

Cleanzones is a leader in building clean rooms Softwall cleanroom and Hardwall cleanroom. Cleanzones builds clean room using Self-powered T-grid HEPA filter ceiling module, air shower, custom fume hoods or stock fume hoods. The fume hoods, exhaust fume hoods and laboratory fume hoods can be incorporated into any module we build.

By combining you cleanroom with exhaust fume hoods, Cleanzones can solve all your needs. Whatever the application for the clean room, we have the answer. From modular clean rooms to custom using Laminar flow work stations or a wet process station. Our wet process stations can include a wet bench.  Cleanzones can fulfill you needs for cleanrooms, portable clean rooms, Modular with pass through and wet process stations. Laminar flow hoods can be incorporated into our custom clean rooms. Our portable cleanroom can be made to your specs. Our portable clean rooms and modular can be incorporated with a wet process station, wet bench, laboratory furniture hood, fume exhaust hood, or an air shower. We also can make Negative flow exhaust workstation and containment work station. The containment work stations is a free-standing console design with a confined work chamber that prevents airborne powder/dust from contaminating the plant or lab atmosphere, or cross-contaminating other products in the air, and protects operator and plant facility.

Our Negative Flow Exhausting HEPA Filtered Workstation is a Free-standing console that provides containment of contaminated air through intake at work chamber. The initial prefilter collects gross contaminants, then the air passes through an exhaust HEPA filter (High Efficiency Particulate Air, 99.99% efficient on .3 microns) for removal of the remaining contaminants to .3 microns.

rss logo!!!!SUBSCRIBE TO OUR NEWS FEEDS BY CLICKING HERE  !!!!rss logo